Lines Matching refs:getTagsForStencil

14 …ontrol mechanism with detachable grip and detent', null, null, this.getTagsForStencil(gn, 'x10010 …
15 …, 'X10020 Plunger with adjustable stroke limiter', null, null, this.getTagsForStencil(gn, 'x10020 …
16 … 'X10030 Push/pull control mechanism with detent', null, null, this.getTagsForStencil(gn, 'x10030 …
17 …0 Control mechanism with locking manual override', null, null, this.getTagsForStencil(gn, 'x10040 …
18 …ing control mechanism with five detent positions', null, null, this.getTagsForStencil(gn, 'x10050 …
19 …r lever for actuation in one direction of travel', null, null, this.getTagsForStencil(gn, 'x10060 …
20 …ntrol mechanism using an electric stepping motor', null, null, this.getTagsForStencil(gn, 'x10070 …
21 …ernal pressure supply using the valve-inlet port', null, null, this.getTagsForStencil(gn, 'x10080 …
22 …rnal pressure supply using the pilot-supply port', null, null, this.getTagsForStencil(gn, 'X10090 …
23 …10100 Pneumatic spring, external pressure supply', null, null, this.getTagsForStencil(gn, 'X10090 …
24 …rection of actuation towards the valving element', null, null, this.getTagsForStencil(gn, 'x10110 …
25 …ction of actuation away from the valving element', null, null, this.getTagsForStencil(gn, 'x10120 …
26 …d the other acting away from the valving element', null, null, this.getTagsForStencil(gn, 'x10130 …
27 …rds the valving element, continuously controlled', null, null, this.getTagsForStencil(gn, 'x10140 …
28 …rom the valving element, continuously controlled', null, null, this.getTagsForStencil(gn, 'x10150 …
29 …rom the valving element, continuously controlled', null, null, this.getTagsForStencil(gn, 'x10160 …
30 …lectrically operated pneumatic control mechanism', null, null, this.getTagsForStencil(gn, 'X10170 …
31 …hydraulic pilot stage with external pilot supply', null, null, this.getTagsForStencil(gn, 'x10180 …
32 …5.54, h * 18.66, '', 'X10190 Mechanical feedback', null, null, this.getTagsForStencil(gn, 'x10190 …
33 …ngs, working in both directions, in one assembly', null, null, this.getTagsForStencil(gn, 'x10200 …
34 …ontrol mechanism, spring return, normally closed', null, null, this.getTagsForStencil(gn, 'x10210 …
35 … normally open, solenoid-actuated, spring return', null, null, this.getTagsForStencil(gn, 'x10220 …
36 … control valve, solenoid-actuated, spring return', null, null, this.getTagsForStencil(gn, 'x10230 …
37 …ve, solenoidoperated, with internal pilot supply', null, null, this.getTagsForStencil(gn, 'X10240 …
38 …using the valve to open to a full-flow condition', null, null, this.getTagsForStencil(gn, 'X10250 …
39 …24, '', 'X10260 3/2 lockout valve with a padlock', null, null, this.getTagsForStencil(gn, 'x10260 …
40 …ver in one direction of travel and spring return', null, null, this.getTagsForStencil(gn, 'x10270 …
41 …ions, controlled by a solenoid and spring return', null, null, this.getTagsForStencil(gn, 'x10280 …
42 …, spring return, and manual override with detent', null, null, this.getTagsForStencil(gn, 'X10290'…
43 …10300 Pulse counter with pneumatic output signal', null, null, this.getTagsForStencil(gn, 'x10300 …
44 …/2 directional control valve, differential pilot', null, null, this.getTagsForStencil(gn, 'x10310 …
45 …, spring return, and manual override with detent', null, null, this.getTagsForStencil(gn, 'x10320 …
46 …ed by two solenoids, with detent (impulse valve)', null, null, this.getTagsForStencil(gn, 'x10330 …
47 …tic pilot control and torsion bar, spring return', null, null, this.getTagsForStencil(gn, 'x10340 …
48 …d by solenoid and hydraulic pilot, spring return', null, null, this.getTagsForStencil(gn, 'x10350 …
49 …centering, external pilot supply and pilot drain', null, null, this.getTagsForStencil(gn, 'x10360 …
50 … solenoids with spring-centered central position', null, null, this.getTagsForStencil(gn, 'x10370 …
51 …l valve, hydraulically controlled, spring return', null, null, this.getTagsForStencil(gn, 'x10380 …
52 …valve, hydraulically controlled, spring-centered', null, null, this.getTagsForStencil(gn, 'x10390 …
53 …/2 directional control valve, treadle-controlled', null, null, this.getTagsForStencil(gn, 'x10400 …
54 …-electric-controlled, return by pneumatic spring', null, null, this.getTagsForStencil(gn, 'x10410 …
55 …, lever-controlled to each position, with detent', null, null, this.getTagsForStencil(gn, 'x10420 …
56 …nal pilot supply, spring return, manual override', null, null, this.getTagsForStencil(gn, 'x10430 …
57 …rnal pressure supply using the valve supply port', null, null, this.getTagsForStencil(gn, 'x10440 …
58 …rnal pressure supply using the pilot supply port', null, null, this.getTagsForStencil(gn, 'x10441 …
59 …xiliary manual control. External pressure supply', null, null, this.getTagsForStencil(gn, 'x10442 …
60 …both sides. Spring return to the centre position', null, null, this.getTagsForStencil(gn, 'x10450 …
61 …valve, mechanical spring and air spring returned', null, null, this.getTagsForStencil(gn, 'x10460 …
62 …let ports open to exhaust in the centre position', null, null, this.getTagsForStencil(gn, 'x10470 …
63 …olenoid-actuated poppet valve, with limit switch', null, null, this.getTagsForStencil(gn, 'x10480 …
64 …, '', 'X10490 3/2 solenoid-actuated poppet valve', null, null, this.getTagsForStencil(gn, 'x10490 …
65 …pening pressure is adjusted by means of a spring', null, null, this.getTagsForStencil(gn, 'x10500 …
66 …equence valve with manually adjustable set point', null, null, this.getTagsForStencil(gn, 'x10510 …
67 …1, '', 'X10520 Sequence valve, with bypass valve', null, null, this.getTagsForStencil(gn, 'x10520 …
68 …', 'X10530 Sequence valve, externally controlled', null, null, this.getTagsForStencil(gn, 'x10530 …
69 …ressure regulator, with internal reversible flow', null, null, this.getTagsForStencil(gn, 'x10540 …
70 …port pressure-reducing valve with external drain', null, null, this.getTagsForStencil(gn, 'x10550 …
71 …port pressure-reducing valve with external drain', null, null, this.getTagsForStencil(gn, 'x10560 …
72 …ote pilot adjusted, relieving, forward flow only', null, null, this.getTagsForStencil(gn, 'x10570 …
73 …avitation valves for protecting two supply lines', null, null, this.getTagsForStencil(gn, 'x10580 …
74 …lve with a fixed switching-pressure differential', null, null, this.getTagsForStencil(gn, 'x10590 …
75 …ectrically operated activation to a set pressure', null, null, this.getTagsForStencil(gn, 'x10600 …
76 …, '', 'X10610 Three-port pressure-reducing valve', null, null, this.getTagsForStencil(gn, 'x10610 …
77 …ressure. The weaker signal is fed to the output.', null, null, this.getTagsForStencil(gn, 'x10620 …
78 …7.57, '', 'X10630 Flow-control valve, adjustable', null, null, this.getTagsForStencil(gn, 'x10630 …
79 …lve, adjustable, with free flow in one direction', null, null, this.getTagsForStencil(gn, 'x10640 …
80 …lve, operated by roller plunger, spring-returned', null, null, this.getTagsForStencil(gn, 'x10650 …
81 …ifferential, adjustable, with bypass check valve', null, null, this.getTagsForStencil(gn, 'x10660 …
82 …inlet flow into a fixed flow and a residual flow', null, null, this.getTagsForStencil(gn, 'x10670 …
83 …hat divides the inlet flow into two outlet flows', null, null, this.getTagsForStencil(gn, 'x10680 …
84 …o inlet flows constant in relation to each other', null, null, this.getTagsForStencil(gn, 'x10690 …
85 … valve, free flow possible in only one direction', null, null, this.getTagsForStencil(gn, 'x10700 …
86 … possible in only one direction, normally closed', null, null, this.getTagsForStencil(gn, 'x10710 …
87 …lot pressure allows free flow in both directions', null, null, this.getTagsForStencil(gn, 'x10720 …
88 … 'X10730 Double non-return valve, pilot-operated', null, null, this.getTagsForStencil(gn, 'x10730 …
89 …ressure is automatically connected to the outlet', null, null, this.getTagsForStencil(gn, 'x10740 …
90 …8.47, h * 37.33, '', 'X10750 Quick-exhaust valve', null, null, this.getTagsForStencil(gn, 'x10750 …
91 …l directional control valve, directly controlled', null, null, this.getTagsForStencil(gn, 'x10760 …
92 …l directional control valve, directly controlled', null, null, this.getTagsForStencil(gn, 'x10770 …
93 …in and pilot stages, with integrated electronics', null, null, this.getTagsForStencil(gn, 'x10780 …
94 …in and pilot stages, with integrated electronics', null, null, this.getTagsForStencil(gn, 'x10790 …
95 … to the pilot stage, with integrated electronics', null, null, this.getTagsForStencil(gn, 'x10800 …
96 …or, mechanical feedback of the cylinder position', null, null, this.getTagsForStencil(gn, 'x10810 …
97 …re, electrical feedback and integral electronics', null, null, this.getTagsForStencil(gn, 'x10820 …
98 …d controls the valve poppet by means of a spring', null, null, this.getTagsForStencil(gn, 'x10830 …
99 …ing on a valve poppet, with integral electronics', null, null, this.getTagsForStencil(gn, 'x10840 …
100 …ol of the solenoid and with integral electronics', null, null, this.getTagsForStencil(gn, 'x10850 …
101 …the solenoid position, with external pilot drain', null, null, this.getTagsForStencil(gn, 'x10860 …
102 …ntrol of the solenoid and integrated electronics', null, null, this.getTagsForStencil(gn, 'x10870 …
103 …um pressure-relief function, with external drain', null, null, this.getTagsForStencil(gn, 'x10880 …
104 …ortional flow-control valve, directly controlled', null, null, this.getTagsForStencil(gn, 'x10890 …
105 …ntrol of the solenoid and integrated electronics', null, null, this.getTagsForStencil(gn, 'x10900 …
106 …the main and pilot stage, integrated electronics', null, null, this.getTagsForStencil(gn, 'x10910 …
107 …oid that is not affected by changes in viscosity', null, null, this.getTagsForStencil(gn, 'x10920 …
108 …l valve cartridge, poppet design, area ratio 1:1', null, null, this.getTagsForStencil(gn, 'x10930'…
109 …ge, poppet design, normally open, area ratio 1:1', null, null, this.getTagsForStencil(gn, 'x10940 …
110 …et design, with throttle nose, area ratio <= 0,7', null, null, this.getTagsForStencil(gn, 'x10950 …
111 …pet design, with throttle nose, area ratio > 0,7', null, null, this.getTagsForStencil(gn, 'x10960 …
112 …alve cartridge, poppet design, area ratio <= 0,7', null, null, this.getTagsForStencil(gn, 'x10970 …
113 …valve cartridge, poppet design, area ratio < 0,7', null, null, this.getTagsForStencil(gn, 'x10980 …
114 …rtridge, poppet design, opened by pilot pressure', null, null, this.getTagsForStencil(gn, 'x10990 …
115 …alve cartridge without area difference on side B', null, null, this.getTagsForStencil(gn, 'x11000 …
116 …ot supply, with replaceable orifice (restrictor)', null, null, this.getTagsForStencil(gn, 'x11010 …
117 …itation functions, spool design, normally closed', null, null, this.getTagsForStencil(gn, 'x110020…
118 …ormally closed, with integrated non-return valve', null, null, this.getTagsForStencil(gn, 'x11030 …
119 … normally open, with integrated non-return valve', null, null, this.getTagsForStencil(gn, 'x11040 …
120 …* 27.76, '', 'X11050 Control cover without ports', null, null, this.getTagsForStencil(gn, 'x11050 …
121 …37.39, '', 'X11060 Control cover with pilot port', null, null, this.getTagsForStencil(gn, 'x11060 …
122 …djustable stroke limiter and remote-control port', null, null, this.getTagsForStencil(gn, 'x11070 …
123 …0 Control cover for mounting additional elements', null, null, this.getTagsForStencil(gn, 'x11080 …
124 …over with hydraulically controlled shuttle valve', null, null, this.getTagsForStencil(gn, 'x11090 …
125 …46, '', 'X11100 Control cover with shuttle valve', null, null, this.getTagsForStencil(gn, 'x11100 …
126 …h shuttle valve for mounting additional elements', null, null, this.getTagsForStencil(gn, 'x11110 …
127 …1120 Control cover with pressure-relief function', null, null, this.getTagsForStencil(gn, 'x11120 …
128 …pressure-relief function and hydraulic unloading', null, null, this.getTagsForStencil(gn, 'x11130 …
129 …a flow-control valve for limiting the pilot flow', null, null, this.getTagsForStencil(gn, 'x11140 …
130 …150 Two-port cartridge valve with stroke limiter', null, null, this.getTagsForStencil(gn, 'x11150 …
131 …dge valve with builtin directional control valve', null, null, this.getTagsForStencil(gn, 'x11160 …
132 …control, with built-in directional control valve', null, null, this.getTagsForStencil(gn, 'x11170 …
133 …rt cartridge valve with pressure-relief function', null, null, this.getTagsForStencil(gn, 'x11180 …
134 …ef function and selectable second pressure stage', null, null, this.getTagsForStencil(gn, 'x11190 …
135 …ment and manual maximum pressure relief function', null, null, this.getTagsForStencil(gn, 'x11200 …
136 … flow-control valve, controlled by high pressure', null, null, this.getTagsForStencil(gn, 'x11210 …
137 …re-reducing function, controlled by low pressure', null, null, this.getTagsForStencil(gn, 'x11220 …
138 …t pump and one direction of rotation (clockwise)', null, null, this.getTagsForStencil(gn, 'x11230 …
139 … line, and one direction of rotation (clockwise)', null, null, this.getTagsForStencil(gn, 'x11240 …
140 …ernal drain line, and two directions of rotation', null, null, this.getTagsForStencil(gn, 'x11250 …
141 … unit with one direction of rotation (clockwise)', null, null, this.getTagsForStencil(gn, 'x11260 …
142 …Pump with a limited swivel angle, lever-operated', null, null, this.getTagsForStencil(gn, 'x11270 …
143 … limited swivel angle and two directions of flow', null, null, this.getTagsForStencil(gn, 'x11280 …
144 …Semi-rotary actuator/swivel drive, single-acting', null, null, this.getTagsForStencil(gn, 'x11290 …
145 … rotation (clockwise) and an external drain line', null, null, this.getTagsForStencil(gn, 'x11300 …
146 …direction (clockwise) and an external drain line', null, null, this.getTagsForStencil(gn, 'x11310 …
147 …n (counter-clockwise) and an external drain line', null, null, this.getTagsForStencil(gn, 'x11320 …
148 …n (counter-clockwise) and an external drain line', null, null, this.getTagsForStencil(gn, 'x11330 …
149 …direction (clockwise) and an external drain line', null, null, this.getTagsForStencil(gn, 'x11340 …
150 …direction (clockwise) and an external drain line', null, null, this.getTagsForStencil(gn, 'x11350 …
151 …direction (clockwise) and an external drain line', null, null, this.getTagsForStencil(gn, 'x11360'…
152 …ent motor with two output directions of rotation', null, null, this.getTagsForStencil(gn, 'x11370 …
153 …cement pump with one drive direction (clockwise)', null, null, this.getTagsForStencil(gn, 'x11380 …
154 …,1,0]]', w * 41.69, h * 46.45, '', 'X11390 Motor', null, null, this.getTagsForStencil(gn, 'x11390 …
155 …]', w * 41.61, h * 46.97, '', 'X11400 Compressor', null, null, this.getTagsForStencil(gn, 'x11400 …
156 …ixed displacement and two directions of rotation', null, null, this.getTagsForStencil(gn, 'x11410 …
157 …', w * 41.75, h * 46.45, '', 'X11420 Vacuum pump', null, null, this.getTagsForStencil(gn, 'x11420 …
158 … pressure p1 into a higher hydraulic pressure p2', null, null, this.getTagsForStencil(gn, 'x11430 …
159 … by spring force, spring chamber with connection', null, null, this.getTagsForStencil(gn, 'x11440 …
160 …, '', 'X11450 Double-acting, single-rod cylinder', null, null, this.getTagsForStencil(gn, 'x11450 …
161 …on both sides with adjustment on right side only', null, null, this.getTagsForStencil(gn, 'x11460 …
162 …ng diaphragm cylinder with preset stroke limiter', null, null, this.getTagsForStencil(gn, 'x11470 …
163 … cap end without the possibility of a connection', null, null, this.getTagsForStencil(gn, 'x11480 …
164 …'X11490 Single-acting cylinder, plunger cylinder', null, null, this.getTagsForStencil(gn, 'x11490 …
165 …, '', 'X11500 Telescopic cylinder, single-acting', null, null, this.getTagsForStencil(gn, 'x11500 …
166 …, '', 'X11510 Telescopic cylinder, double-acting', null, null, this.getTagsForStencil(gn, 'x11510 …
167 …-position cushioning on both sides of the piston', null, null, this.getTagsForStencil(gn, 'x11520 …
168 …-position cushioning on both sides of the piston', null, null, this.getTagsForStencil(gn, 'x11530 …
169 …nder with position switch on right-hand end only', null, null, this.getTagsForStencil(gn, 'x11540 …
170 …cylinder with detents at both ends of the stroke', null, null, this.getTagsForStencil(gn, 'x11550 …
171 …itch on the right end, tripped by the piston rod', null, null, this.getTagsForStencil(gn, 'x11560 …
172 …sure into a hydraulic pressure of the same value', null, null, this.getTagsForStencil(gn, 'x11570 …
173 … pressure p1 into a higher hydraulic pressure p2', null, null, this.getTagsForStencil(gn, 'x11580 …
174 … pressure p1 into a higher hydraulic pressure p2', null, null, this.getTagsForStencil(gn, 'x11590 …
175 … w * 37.52, h * 28, '', 'X11600 Bellows cylinder', null, null, this.getTagsForStencil(gn, 'x11600 …
176 … w * 46.69, h * 19.07, '', 'X11610 Hose cylinder', null, null, this.getTagsForStencil(gn, 'x11610 …
177 …ouble-acting with permanent magnet on the piston', null, null, this.getTagsForStencil(gn, 'x11620 …
178 …r, double-acting with permanent magnet on piston', null, null, this.getTagsForStencil(gn, 'x11630 …
179 …r, double-acting with permanent magnet on piston', null, null, this.getTagsForStencil(gn, 'x11640 …
180 …r, single-acting with permanent magnet on piston', null, null, this.getTagsForStencil(gn, 'x11650 …
181 …r, single-acting with permanent magnet on piston', null, null, this.getTagsForStencil(gn, 'x11660 …
182 …, w * 20.03, h * 6.68, '', 'X11670 Hose assembly', null, null, this.getTagsForStencil(gn, 'x11670 …
183 …* 25.43, '', 'X11680 Three-way rotary connection', null, null, this.getTagsForStencil(gn, 'x11680 …
184 …ion coupling without non-return valve, uncoupled', null, null, this.getTagsForStencil(gn, 'x11690 …
185 …action coupling with non-return valve, uncoupled', null, null, this.getTagsForStencil(gn, 'x11700 …
186 …n coupling with two non-return valves, uncoupled', null, null, this.getTagsForStencil(gn, 'x11710 …
187 …ction coupling without non-return valve, coupled', null, null, this.getTagsForStencil(gn, 'x11720 …
188 …tion coupling with one non-return valve, coupled', null, null, this.getTagsForStencil(gn, 'x11730 …
189 …ion coupling with two non-return valves, coupled', null, null, this.getTagsForStencil(gn, 'x11740 …
190 … Pressure switch, electro-mechanical, adjustable', null, null, this.getTagsForStencil(gn, 'x11750 …
191 …lectronically adjustable switching signal output', null, null, this.getTagsForStencil(gn, 'x11760 …
192 … 'X11770 Pressure sensor, analogue output signal', null, null, this.getTagsForStencil(gn, 'x11770 …
193 …28, '', 'X11780 Piezo-electric control mechanism', null, null, this.getTagsForStencil(gn, 'x11780 …
194 … 23.06, h * 13.87, '', 'X11790 Optical indicator', null, null, this.getTagsForStencil(gn, 'x11790 …
195 …3.87, '', 'X11800 Indicator with digital display', null, null, this.getTagsForStencil(gn, 'x11800 …
196 …23.06, h * 13.87, '', 'X11810 Acoustic indicator', null, null, this.getTagsForStencil(gn, 'x11810 …
197 …'X11820 Pressure-measuring unit (pressure gauge)', null, null, this.getTagsForStencil(gn, 'x11820 …
198 …* 37.38, '', 'X11830 Differential-pressure gauge', null, null, this.getTagsForStencil(gn, 'x11830 …
199 … '', 'X11840 Pressure gauge with select function', null, null, this.getTagsForStencil(gn, 'x11840 …
200 …', w * 18.67, h * 28.09, '', 'X11850 Thermometer', null, null, this.getTagsForStencil(gn, 'x11850 …
201 … electrical break-contacts (contact thermometer)', null, null, this.getTagsForStencil(gn, 'x11860 …
202 … '', 'X11870 Fluid-level indicator (sight-glass)', null, null, this.getTagsForStencil(gn, 'x11870 …
203 …1880 Fluid-level switch with four break-contacts', null, null, this.getTagsForStencil(gn, 'x11880 …
204 … with analogue output signal and digital display', null, null, this.getTagsForStencil(gn, 'x11890 …
205 …w * 18.67, h * 28.09, '', 'X11900 Flow indicator', null, null, this.getTagsForStencil(gn, 'x11900 …
206 …]', w * 18.67, h * 37.52, '', 'X11910 Flow meter', null, null, this.getTagsForStencil(gn, 'x11910 …
207 ….52, '', 'X11920 Flow meter with digital display', null, null, this.getTagsForStencil(gn, 'x11920 …
208 …]', w * 28.14, h * 18.71, '', 'X11930 Tachometer', null, null, this.getTagsForStencil(gn, 'x11930 …
209 …, w * 37.47, h * 18.71, '', 'X11940 Torque meter', null, null, this.getTagsForStencil(gn, 'x11940 …
210 …* 13.91, '', 'X11950 Time controller with switch', null, null, this.getTagsForStencil(gn, 'x11950 …
211 …,0]]', w * 27.91, h * 18.57, '', 'X11960 Counter', null, null, this.getTagsForStencil(gn, 'x11960 …
212 … h * 32.33, '', 'X11970 In-line particle counter', null, null, this.getTagsForStencil(gn, 'x11970 …
213 …1,0]]', w * 26.22, h * 45.06, '', 'X11980 Filter', null, null, this.getTagsForStencil(gn, 'x11980 …
214 …h * 47.81, '', 'X11990 Reservoir-breather filter', null, null, this.getTagsForStencil(gn, 'x11990 …
215 … 'X12000 Filter with additional magnetic element', null, null, this.getTagsForStencil(gn, 'x12000 …
216 …, 'X12010 Filter with optical clogging indicator', null, null, this.getTagsForStencil(gn, 'x12010 …
217 …X12020 Filter with pressure-measuring instrument', null, null, this.getTagsForStencil(gn, 'x12020 …
218 … '', 'X12030 Filter with a throttled bypass flow', null, null, this.getTagsForStencil(gn, 'x12030 …
219 …, h * 73.5, '', 'X12040 Filter with bypass valve', null, null, this.getTagsForStencil(gn, 'x12040 …
220 …0 Filter with bypass valve and digital indicator', null, null, this.getTagsForStencil(gn, 'x12050 …
221 …ptical clogging indicator and electrical contact', null, null, this.getTagsForStencil(gn, 'x12060 …
222 …logging indicator based on differential pressure', null, null, this.getTagsForStencil(gn, 'x12070 …
223 …sure-measuring instrument and electrical contact', null, null, this.getTagsForStencil(gn, 'x12080 …
224 ….21, h * 26.2, '', 'X12090 Centrifugal separator', null, null, this.getTagsForStencil(gn, 'x12090 …
225 …, 'X12100 Coalescing filter with automatic drain', null, null, this.getTagsForStencil(gn, 'x12100 …
226 … filter with manual drain and clogging indicator', null, null, this.getTagsForStencil(gn, 'x12110 …
227 …45.21, h * 26.2, '', 'X12120 Two-phase separator', null, null, this.getTagsForStencil(gn, 'x12120 …
228 … * 45.21, h * 26.2, '', 'X12130 vacuum separator', null, null, this.getTagsForStencil(gn, 'x12130 …
229 …1, h * 26.2, '', 'X12140 Electrostatic separator', null, null, this.getTagsForStencil(gn, 'x12140 …
230 …adjustment, nonrelieving, without pressure gauge', null, null, this.getTagsForStencil(gn, 'x12150 …
231 …nt, a pressure gauge and a lubricator (detailed)', null, null, this.getTagsForStencil(gn, 'x12160 …
232 …, a pressure gauge and a lubricator (simplified)', null, null, this.getTagsForStencil(gn, 'x12160 …
233 …170 Double filter with manual changeover feature', null, null, this.getTagsForStencil(gn, 'x12170 …
234 …4, '', 'X12180 Fluid separator with manual drain', null, null, this.getTagsForStencil(gn, 'x12180 …
235 … 'X12190 Filter with separator with manual drain', null, null, this.getTagsForStencil(gn, 'x12190 …
236 …'', 'X12200 Fluid separator with automatic drain', null, null, this.getTagsForStencil(gn, 'x12200 …
237 … * 45.21, h * 35.67, '', 'X12210 Adsorber filter', null, null, this.getTagsForStencil(gn, 'x12210 …
238 …45.21, h * 35.67, '', 'X12220 Oil mist separator', null, null, this.getTagsForStencil(gn, 'x12220 …
239 …]]', w * 45.21, h * 35.67, '', 'X12230 Air dryer', null, null, this.getTagsForStencil(gn, 'x12230 …
240 …]]', w * 55.85, h * 26.2, '', 'X12240 Lubricator', null, null, this.getTagsForStencil(gn, 'x12240 …
241 … 39.34, '', 'X12250 Lubricator with manual drain', null, null, this.getTagsForStencil(gn, 'x12250 …
242 …hout indication of the flow paths of the coolant', null, null, this.getTagsForStencil(gn, 'x12260 …
243 …h * 49.8, '', 'X12270 Cooler with liquid coolant', null, null, this.getTagsForStencil(gn, 'x12270 …
244 …'', 'X12280 Cooler with electrically powered fan', null, null, this.getTagsForStencil(gn, 'x12280 …
245 …,1,0]]', w * 26.22, h * 49.8, '', 'X12290 Heater', null, null, this.getTagsForStencil(gn, 'x12290 …
246 ….8, h * 26.28, '', 'X12300 Temperature regulator', null, null, this.getTagsForStencil(gn, 'x12300 …
247 …5.68, '', 'X12310 Reclassifier with manual drain', null, null, this.getTagsForStencil(gn, 'x12310 …
248 …ated by a diaphragm (diaphragm-type accumulator)', null, null, this.getTagsForStencil(gn, 'x12320 …
249 …eparated by a bladder (bladder-type accumulator)', null, null, this.getTagsForStencil(gn, 'x12330 …
250 …ton and piston bladder (piston-type accumulator)', null, null, this.getTagsForStencil(gn, 'x12340 …
251 …]', w * 18.53, h * 46.46, '', 'X12350 Gas bottle', null, null, this.getTagsForStencil(gn, 'x12350 …
252 …2360 Piston-type accumulator with back-up bottle', null, null, this.getTagsForStencil(gn, 'x12360 …
253 … w * 56.27, h * 18.57, '', 'X12370 Air reservoir', null, null, this.getTagsForStencil(gn, 'x12370 …
254 …* 56.13, h * 27.96, '', 'X12380 Vacuum generator', null, null, this.getTagsForStencil(gn, 'x12380 …
255 …acuum generator with integrated non-return valve', null, null, this.getTagsForStencil(gn, 'x12390 …
256 …cuum generator with integrated non-return valves', null, null, this.getTagsForStencil(gn, 'x12400 …
257 …ingle stage vacuum generator with blow-off valve', null, null, this.getTagsForStencil(gn, 'x12410 …
258 …', w * 18.69, h * 28.39, '', 'X12420 Suction cup', null, null, this.getTagsForStencil(gn, 'x12420 …
259 …cup with spring loaded stem and non-return valve', null, null, this.getTagsForStencil(gn, 'x12430 …